A material certificate is not a CE mark, and a test report is not an approval. This is the paperwork a mouth guard factory can hand over, and the claims it should refuse to make.
Compliance questions on mouth guards usually arrive as one sentence: can you send your certificates? There is no single certificate, because a guard is covered by several regimes at once. A material is assessed for food contact, a product may fall under protective equipment rules, a market may require a responsible person, and a brand may want to print a claim.
Start with the material, not the certificate folder
Ask for the grade first. A food-contact declaration is only meaningful when it names a specific grade from a specific compounder, because the declaration follows the formulation and not the shape of the finished part. If a supplier sends a certificate with no grade name, no manufacturer and no date, it cannot be traced to the sheet that went into your guard.
Our shells are moulded from food-grade EVA, TPE and transparent EVA, with a gel liner where the design calls for one and a TPU tether where a strap is fitted. Each of those is a separate material with its own declaration, so a complete file has one document per material in the bill, not one document for the product.
Food-contact documentation: what the papers should say
For a guard that goes in a mouth, the relevant question is whether the material is suitable for repeated contact with food and saliva. That is a materials question, and the answer lives in a small set of documents:
- Material data sheet with the grade code, the compounder and the lot, so the sheet can be matched to the batch record.
- Food-contact declaration under the framework regulation for food contact materials in the destination market, naming the intended use and the contact conditions.
- Migration test results from an accredited laboratory, with the sample identified by grade and the test conditions stated.
- Phthalate statement confirming that no restricted phthalate plasticiser is present in the formulation.
- Heavy metal and colourant statement for any masterbatch used to colour the shell.
The order of those documents matters. The data sheet identifies the material, the declaration states what it may be used for, and the test report is evidence for a sample of that material. If the test report names a different grade from the data sheet, the chain is broken and the file is not usable in a due diligence review.
Phthalates, REACH and the declaration chain
Phthalate-free is a statement about the formulation, not a property of the colour. EVA and TPE do not need phthalate plasticisers to be flexible, so the claim should be backed by a screening test rather than a sentence in a brochure.
For the European market, REACH adds a second layer. Substances on the candidate list of substances of very high concern carry a communication duty once they are present above the threshold in an article, which means your declaration has to state whether any candidate list substance is present and at what level. Below that threshold, the declaration is a negative statement, and it still needs a date and a scope.
SVHC declarations also expire in usefulness: one from several seasons ago may not reflect the current candidate list, so ask for a dated declaration that covers the material you are actually ordering.
FDA 21 CFR 177.2600 and what it does not mean
For food-contact elastomers, the citation most often quoted is FDA 21 CFR 177.2600, the section covering rubber articles intended for repeated use. It sets out which ingredients may be used and what extraction limits apply, and for a TPE compound it is the right place to look.
Two cautions. First, 177.2600 is written for rubber articles, so a supplier who sends a 177.2600 certificate for an EVA shell, which is a plastic rather than a rubber, has attached the wrong document. Ask which citation applies to that grade. Second, compliance with a food-contact regulation is not an approval. The FDA does not issue a certificate for a mouth guard, so the phrase approved by the FDA is not something a factory can support.
CE marking: what it is and when it applies
A CE mark is a declaration by the party placing the product on the European market that it meets the applicable harmonisation legislation. It is not a test report, it is not issued by a laboratory, and it does not exist in the abstract: it always points to a specific directive or regulation.
For a mouth guard, whether CE applies depends on how the product is presented. If it is sold as protective equipment rather than as a sports accessory, the PPE Regulation (EU) 2016/425 applies, and the conformity route involves a notified body for the type examination before the manufacturer draws up the declaration of conformity. If it is sold as an accessory with no protective claim, the CE mark has no legal basis and should not be printed.
That difference has a commercial consequence. The brand that places the guard on the market signs the declaration of conformity and holds the technical file. A factory can supply the material evidence, batch records and test reports that go into that file, but it cannot sign in your name.
What a factory can supply, and what it cannot
The table below is the line we hold with every buyer. It is deliberately narrow, because everything on the right hand side is a claim that needs a document the factory does not own.
| Item | Factory can supply | Factory cannot supply |
|---|---|---|
| Material identity | Grade name, compounder, data sheet, lot record | A grade change disguised as the same product |
| Food contact | Declaration and migration report for the grade used | An approval certificate, because none is issued |
| Phthalates | Formulation statement plus screening test | A guarantee that covers materials it did not buy |
| REACH | Dated SVHC declaration for the shipped material | A declaration for a different grade or an older list |
| CE marking | Technical file inputs, batch traceability, test evidence | A signed declaration of conformity in your name |
| Medical claims | Material evidence you can assess | Medical device status, or a clinical claim |
| Federation approval | Nothing, unless the federation paperwork exists | An approved by statement with no letter behind it |
| Inspection | Pre-shipment report at AQL 2.5 | A third party audit result it did not commission |
Claims that get brands into trouble
The claims that cause trouble are rarely invented by the factory. They usually start as a line in a brand deck and end up on a sleeve. Four of them are worth refusing on principle.
Approved by a sports federation. A federation approval is a licence or a listing, and it exists as a letter, a certificate number or a published equipment list. Without that document, the claim is unverified, and the brand that prints it carries the exposure. If a supplier says it is approved, ask for the paperwork naming your product.
Medical grade or clinically proven. A mouth guard is not a medical device unless it is placed on the market as one, which requires a technical file, a biological evaluation and a conformity route of its own. A material can be tested for biocompatibility, but a test on a material is not a clinical claim about a product.
FDA approved. Compliance with a food-contact regulation is a statement about ingredients and extraction limits. It is not an approval, and no factory holds a certificate that says otherwise.
CE marked for all markets. A CE mark is European, and it applies to the legislation the product falls under. Printing it on a product sold outside that scope is a claim without a basis.
A document checklist before you print a claim
Before artwork is signed off, run the file against the claim you want to print. The checklist saves a reprint.
- The material data sheet names the grade and the compounder, and matches the batch record.
- The food-contact declaration names the intended use and the contact conditions for your product.
- The migration report names the same grade as the data sheet and comes from an accredited laboratory.
- The phthalate statement is dated and sits alongside a screening result, not instead of one.
- The REACH SVHC declaration is dated and covers the material in the order.
- The CE position is written down: which legislation, which conformity route, and who signs.
- The pre-shipment inspection is agreed at AQL 2.5, with the report sent before the balance payment.
- The batch code on the pack can be traced back to the inspection report and the material lot.
None of this is exotic. It is the ordinary paperwork of a factory that buys known grades and keeps records, and it is the reason our sampling runs 5 to 7 days and production runs 12 to 18 days after approval: the documents travel with the batch, not after it.
If a claim on your sleeve cannot survive that list, change the claim. A sentence about a 5.5 mm shell and a 5,000 cycle case is defensible and it sells; a badge nobody can evidence is a liability with a barcode.